Suitable For Onosokki Speedometer EC-2100 Elevator Speedometer Japan
- Product SKU: 10027968925613

- Order within
Packing List
EC-2100It's a kind of small and light machine、Hand held elevator speedometer with battery,For elevator adjustment,maintain,inspect。Comparison of previous models(EC-900),Extension of measurement range2Times2000 m/min,The calculation time is reduced to1/10achieve10 ms,It can be used to measure the speed and speed of high-speed elevator。The elevator speedometer gently contacts the sling pulley of the elevator traction machine,You can measure the speed of the elevator。The indicator is redLED,Easy to observe and identify。Dark places,It is also convenient to read test data。In addition, if the use of supporting fixed appliances fixedEC-2100This machine or use optionsEC-0201External detector,Even one person can complete the elevator speed test alone。 EC-2100The measured value can be locked and maintained by using the function button on the machine or external input signal,To ensure the smooth progress of measurement, high reliability。Chen Wen13427905234 0755-36528580 This machine has2Two indicators,It can be locked and held separately2Two measured values。IfEC-2100Additional optionsEC-0202Distance measurement function,It can also complete the moving distance of the elevator within the set time(mm)measure。 EC-2100Additional optionsEC-0202Distance measurement functionAnd optionsEC-0203Trigger device,The stopping distance for emergency stop of escalatormeasure。
\nSpecialty
\n- \n
- \n
measureWide range2000 m/min,The calculation time is short10 ms,Speed or speed at high speedmeasure。
\n - \n
With data saving function,Can be saved10Group data
\n - \n
Standard configurationmeasureAnalog voltage output of the value,Pulse output
\n - \n
Large value holding function,Can be maintainedmeasureLarge value in
\n - \n
Average processing function,measurespeed,Average calculation of speed value(Average times1-200,It can be set at will)
\n - \n
Automatic power off,Expression of battery residual。Chen Wen13427905234 0755-36528580
\n - \n
Using optionsEC-0202Distance measurement function,It can complete the moving distance of the elevator within the set timemeasure(Rotation direction symbol can be set freely)
\n - \n
Using optionsEC-0201External detector,Can be far away frommeasurePoint to gomeasure。
\n - \n
Using optionsZhou SuhuanKS-300,It can be used as a hand-held tachometer
\n - \n
EC-2100 Elevator.speedmeter
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nmeasure mode Contact type measureRange \n speed: 0.1 ~ 2,000.0 m/min
\n
speed: 1 ~ 20,000 r/min
distance:0 ~ ±999 mm**measurevalueRangeYes±5000 mm,But beyond that±999 mmThe above numerical accuracy cannot be guaranteed。
measureaccuracy ± 1Counts measuretime 10 ms monitor gulesLED 5position,2group Represents an updatetime 100 ms resolving power \n speed:0.1 m/min*,speed:0.1 r/min*,distance:1 mm(Using the optional function)
\n*Average times10Above。Chen Wen13427905234 0755-36528580
measurevaluesingleposition speed: m/min,speed: r/min,distance:mm(Using the optional function) Automatic power off The final operation is finished180 The power is off in seconds Data holding function monitor1,monitor2,largevalue(Separate and independent) averagemeterCalculation function 1 ~ 200 second(It can be set at will) Storage function preservation10groupmeasureResult data Analog output outputvalue instantaneousvalue(afteraveragemeterCalculation processing) VoltageRange 0 ~ 1 V/0 ~ F.S. transformationmode 10 bit D/Atransformation Linearity ±1% F.S. Output updatetime 10 ms line out φ2.5 mm Jack Pulse output outputmode transistoroutput(Open collector) ToleranceVoltage 14 V electric current 20 mA within Number of pulses 600pulse/1turn logic negativelogic pulseSheet about0.5 ~ 1.2 μs line out φ2.5 mm Jack testing produceNumber of pulses 150pulse / eachturn(Narrow projectionmode) light source Infrared light emitting diode Light receiving element photosensitivetransistor allownegativeLotus axial 5 kg、radial 5 kg Bearing life 2×107 r/min??h (At the end of the specificationlargenegativeLotusTime) other Power Supply No. five batteries3section Battery usagetime Continuous use15More than hours(At room temperature) consumeelectric current large 100 mA (Power SupplyVoltage 4.5 V) Service temperatureRange 0 ~ 45℃ preservationtemperatureRange -10 ~ 60℃ Dimensions 60(W)×162(L)×38(D)mm(Compared with the previous modelEC-900identical) weight about 423g(Including batteries,But not includedZhou Suhuan) enclosure \n - \n
- Cable for external data holding signal(1.4 m):EC-0922 1set(2root)\n
- Carrying case:EC-0925 1individual\n
- Hexagon wrench(Opposite side 1.5 mm):1individual\n
- Dry cell No.5:3section\n
- Chen Wen 13427905234 0755-36528580
be careful:EC-2100In use,Need to match optionsZhou Suhuan(KS-400、KS-500、KS-800)Or optionalspeedContact rod Chen Wen13427905234 0755-36528580(KS-300、EC-0924)use。
^_^:5ec539954e73346ce87822965f003ad6

Packing List
EC-2100It's a kind of small and light machine、Hand held elevator speedometer with battery,For elevator adjustment,maintain,inspect。Comparison of previous models(EC-900),Extension of measurement range2Times2000 m/min,The calculation time is reduced to1/10achieve10 ms,It can be used to measure the speed and speed of high-speed elevator。The elevator speedometer gently contacts the sling pulley of the elevator traction machine,You can measure the speed of the elevator。The indicator is redLED,Easy to observe and identify。Dark places,It is also convenient to read test data。In addition, if the use of supporting fixed appliances fixedEC-2100This machine or use optionsEC-0201External detector,Even one person can complete the elevator speed test alone。 EC-2100The measured value can be locked and maintained by using the function button on the machine or external input signal,To ensure the smooth progress of measurement, high reliability。Chen Wen13427905234 0755-36528580 This machine has2Two indicators,It can be locked and held separately2Two measured values。IfEC-2100Additional optionsEC-0202Distance measurement function,It can also complete the moving distance of the elevator within the set time(mm)measure。 EC-2100Additional optionsEC-0202Distance measurement functionAnd optionsEC-0203Trigger device,The stopping distance for emergency stop of escalatormeasure。
\nSpecialty
\n- \n
- \n
measureWide range2000 m/min,The calculation time is short10 ms,Speed or speed at high speedmeasure。
\n - \n
With data saving function,Can be saved10Group data
\n - \n
Standard configurationmeasureAnalog voltage output of the value,Pulse output
\n - \n
Large value holding function,Can be maintainedmeasureLarge value in
\n - \n
Average processing function,measurespeed,Average calculation of speed value(Average times1-200,It can be set at will)
\n - \n
Automatic power off,Expression of battery residual。Chen Wen13427905234 0755-36528580
\n - \n
Using optionsEC-0202Distance measurement function,It can complete the moving distance of the elevator within the set timemeasure(Rotation direction symbol can be set freely)
\n - \n
Using optionsEC-0201External detector,Can be far away frommeasurePoint to gomeasure。
\n - \n
Using optionsZhou SuhuanKS-300,It can be used as a hand-held tachometer
\n - \n
EC-2100 Elevator.speedmeter
\n \n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nmeasure mode Contact type measureRange \n speed: 0.1 ~ 2,000.0 m/min
\n
speed: 1 ~ 20,000 r/min
distance:0 ~ ±999 mm**measurevalueRangeYes±5000 mm,But beyond that±999 mmThe above numerical accuracy cannot be guaranteed。
measureaccuracy ± 1Counts measuretime 10 ms monitor gulesLED 5position,2group Represents an updatetime 100 ms resolving power \n speed:0.1 m/min*,speed:0.1 r/min*,distance:1 mm(Using the optional function)
\n*Average times10Above。Chen Wen13427905234 0755-36528580
measurevaluesingleposition speed: m/min,speed: r/min,distance:mm(Using the optional function) Automatic power off The final operation is finished180 The power is off in seconds Data holding function monitor1,monitor2,largevalue(Separate and independent) averagemeterCalculation function 1 ~ 200 second(It can be set at will) Storage function preservation10groupmeasureResult data Analog output outputvalue instantaneousvalue(afteraveragemeterCalculation processing) VoltageRange 0 ~ 1 V/0 ~ F.S. transformationmode 10 bit D/Atransformation Linearity ±1% F.S. Output updatetime 10 ms line out φ2.5 mm Jack Pulse output outputmode transistoroutput(Open collector) ToleranceVoltage 14 V electric current 20 mA within Number of pulses 600pulse/1turn logic negativelogic pulseSheet about0.5 ~ 1.2 μs line out φ2.5 mm Jack testing produceNumber of pulses 150pulse / eachturn(Narrow projectionmode) light source Infrared light emitting diode Light receiving element photosensitivetransistor allownegativeLotus axial 5 kg、radial 5 kg Bearing life 2×107 r/min??h (At the end of the specificationlargenegativeLotusTime) other Power Supply No. five batteries3section Battery usagetime Continuous use15More than hours(At room temperature) consumeelectric current large 100 mA (Power SupplyVoltage 4.5 V) Service temperatureRange 0 ~ 45℃ preservationtemperatureRange -10 ~ 60℃ Dimensions 60(W)×162(L)×38(D)mm(Compared with the previous modelEC-900identical) weight about 423g(Including batteries,But not includedZhou Suhuan) enclosure \n - \n
- Cable for external data holding signal(1.4 m):EC-0922 1set(2root)\n
- Carrying case:EC-0925 1individual\n
- Hexagon wrench(Opposite side 1.5 mm):1individual\n
- Dry cell No.5:3section\n
- Chen Wen 13427905234 0755-36528580
be careful:EC-2100In use,Need to match optionsZhou Suhuan(KS-400、KS-500、KS-800)Or optionalspeedContact rod Chen Wen13427905234 0755-36528580(KS-300、EC-0924)use。
^_^:5ec539954e73346ce87822965f003ad6